Forced Air Cooling Machine 2000 kg/h

Pre-cooling unit that pulls chilled air through stacked cartons or bins of produce on a tunnel or plenum arrangement, removing field heat before storage, transport or processing.

SKU: VL-100 Category: Tag:

Forced Air Cooling Machine 2000 kg/h

Forced air cooling machine pulling chilled air through stacked cartons of produce

Pre-cooling unit for the hours that decide how long produce lasts. Field heat is the enemy from the moment a crop is picked: a berry picked at 30 °C and cooled slowly loses days of shelf life that no amount of cold storage afterwards gives back. Forced air cooling is the fastest practical way to take that heat out of packaged produce, and it is cheaper than the two alternatives because it uses air rather than water or vacuum.

How it works

Cartons or bins are stacked so that their vents line up, and the stack is sealed against a plenum — a duct or a wall opening connected to a fan. The fan pulls air, rather than pushes it, creating a pressure difference across the stack: chilled air is drawn from the room, through the vents, through the packaging and around the product, and into the plenum. Because the air moves through the package rather than around it, cooling is far faster than simply standing the load in a cold room.

The two settings that matter are air temperature and airflow. Air at 0-5 °C is standard; too cold and chilling injury appears on tropical and some stone fruit. Airflow is set by the fan and by how well the load seals against the plenum — a gap at the edge of the stack is air that bypasses the product entirely, which is the most common reason a cooling cycle underperforms. Reversible designs alternate the flow direction to even out the temperature gradient across the load.

Suitable for

Berries, leafy vegetables, stone fruit and other high-respiration produce where field heat has to come out fast; packing houses running cartons or bins with vented packaging; operations feeding cold storage or transport, where pre-cooled product holds the cold chain instead of fighting it; plants that cannot justify vacuum cooling’s capital cost and do not want the wet load that hydro-cooling leaves; produce that must stay dry — cartons, not loose product.

Not suitable for

Loose or unpackaged product, which needs hydro-cooling or immersion instead; produce sold wet or needing washing at the same step; unvented packaging, where air cannot pass through the load and the method does nothing; operations without a chilled air source — this machine moves cold air, it does not make it, so a refrigeration plant or cold room is part of the installation; anyone unable to discipline the stacking, because a badly sealed load is the failure mode.

Material & compliance

Frame, plenum and product-contact surfaces in SUS304 (EN 1.4301) or food-grade lined surfaces; fan and ducting arranged for clean-out, because a cooling plenum handling plant debris accumulates it. Air filters accessible and cleaned on a schedule, since the air passing over the product is the air the product is sold with. Temperature recording at supply and at product core is the control evidence most buyers ask for.

Supplied with CE declaration of conformity and DoC on request; material certificate EN 10204 3.1 available for contact parts.

Selection notes

Ask for cooling time measured from field temperature to target core temperature on your product in your packaging, not a generic figure — packaging vents and stack geometry dominate the result. Ask whether the design is one-way or reversible and what that does to temperature uniformity across a pallet. Check the sealing arrangement between load and plenum, because that is where installations lose performance. Check the refrigeration capacity behind it: this machine is an air mover, and the cooling comes from somewhere else.

When you should not buy this machine: If your product is unpackaged or you want it washed at the same step, hydro-cooling is the better tool. And if you need cooling in minutes rather than hours, only vacuum cooling gets there — forced air is fast compared with a cold room and slow compared with vacuum, and buyers who confuse the two end up disappointed.

Key specifications

Parameter Value
Capacity 1000-5000 kg/h by load size and product (TYPICAL, confirm with factory)
Supply air 0-5 °C chilled air (TYPICAL)
Cooling time 1-6 h by product, load and packaging (TYPICAL)
Airflow One-way or reversible plenum pull by design
Load Pallet, carton or bin by configuration
Contact material SUS304 (EN 1.4301) frame; food-grade surfaces
Power supply 380V/3P/50Hz or 415V/3P/50Hz, customizable

Specification values are industry-typical ranges for this machine class and are not verified against a specific factory datasheet. Replace them with measured factory data before publication.

FAQ

Is forced air cooling faster than a cold room?

Much faster — typically several times faster for the same product in vented packaging. A cold room cools the outside of the load; forced air pulls chilled air through it, which is why the method exists.

Why do some cartons cool and others do not?

Air follows the path of least resistance. A gap between the load and the plenum, or blocked vents, lets air bypass the product. Stack discipline and vent alignment are the two things that make this method work.

Does it make cold?

No. It moves chilled air. The cooling comes from a refrigeration plant or cold room already on site, and the forced air unit is the delivery method — size the refrigeration separately when you plan it.

Related equipment

This unit is one stage of a complete processing line. For the full range of cooking and blanching equipment, or to compare this model against the Vacuum Cooling Machine 1000 kg/cycle, see the complete equipment catalogue. Capacity, material grade and utility requirements can be confirmed through a quote request.

material

SUS304 (EN 1.4301)

power

380V/3P/50Hz, Customizable

certification

CE+DoC (EU 2023/1230 ready)

surface_finish

Ra≤0.8 μm (food-grade)

application

Berries, Leafy Vegetables, Stone Fruit

capacity

1–5 t/h

automation

Semi-Automatic, Fully Automatic

cooling_method

Forced Air, Plenum Pull

Reviews

There are no reviews yet.

Be the first to review “Forced Air Cooling Machine 2000 kg/h”